ArcGIS REST Services Directory
|
Login
|
WMAS/SW_Structures (OGCFeatureServer)
ID: 2975
AncillaryRole: 0
OBJECTID: 2975
ST_ID: 04-03-MH-1961
TYPE: MANHOLE
LID_TYPE: GRATE
LID_MAT: CAST IRON
STRUCT_MAT: PRE-CAST CONC
DEPTH_ft: -9.8
CONDITION: GOOD
REHAB: NO REHAB
ACCESS: NA
FLOW: YES
FLOODING: NO
DEBRIS: NONE
CLEANING: NO
ILLICIT: NO
FLAG: NO
Num_INVTS: 4
SIZ_1_in: 24
TYP_1: CPP
DIR_1: N
INV_1_ft: -9.8
SIZ_2_in: 12
TYP_2: PVC
DIR_2: NE
INV_2_ft: -9.8
SIZ_3_in: 12
TYP_3: PVC
DIR_3: S
INV_3_ft: -7.5
SIZ_4_in: 18
TYP_4: CPP
DIR_4: W
INV_4_ft: -9.8
SIZ_5_in: 0
TYP_5:
DIR_5:
INV_5_ft: 0
SIZ_6_in: 0
TYP_6:
DIR_6:
INV_6_ft: 0
METHOD: FIELD
RIM_E: 855.19335937
INVERT: 845.39335937
YEAR_: 2009
PROJECT: Milford High School Additions
FILE_NO: 1535
GRID_CODE: 855.19335937
INV_ELV_1: 845.39335937
INV_ELV_2: 845.39335937
INV_ELV_3: 847.69335937
INV_ELV_4: 845.39335937
Enabled: 1
COMMENT: Outlet smaller than inlets!!! 24" -> 18" !!!
GlobalID: {1A411668-B407-4B79-9D5E-1D0ADCA1D1A3}
Point: [...]