ArcGIS REST Services Directory
|
Login
|
WMAS/SW_Structures (OGCFeatureServer)
ID: 1540
OBJECTID: 1540
ST_ID: 04-02-MH-1303
TYPE: MANHOLE
LID_TYPE: VENTED
LID_MAT: CAST IRON
STRUCT_MAT: POURED CONC
DEPTH_ft: -17.7
Num_INVTS: 2
SIZ_1_in: 30
TYP_1: CMP
DIR_1: North
INV_1_ft: -9.8
SIZ_2_in: 30
TYP_2: CMP
DIR_2: SW
INV_2_ft: -17.7
SIZ_3_in: 0
TYP_3:
DIR_3:
INV_3_ft: 0
SIZ_4_in: 0
TYP_4:
DIR_4:
INV_4_ft: 0
SIZ_5_in: 0
TYP_5:
DIR_5:
INV_5_ft: 0
SIZ_6_in: 0
TYP_6:
DIR_6:
INV_6_ft: 0
METHOD: FIELD
RIM_E: 0
INVERT: 797.24836425
YEAR_:
PROJECT:
FILE_NO:
X: 0
Y: 0
GRID_CODE: 814.94836425
INV_ELV_1: 805.14836425
INV_ELV_2: 797.24836425
INV_ELV_3: 0
INV_ELV_4: 0
INV_ELV_5: 0
INV_ELV_6: 0
COMMENT: Field measured #1 as 36", but plans show 30", and MH1303 has 30" outfall
EID:
Verify:
GlobalID_2: {DBE6B88C-601E-431D-A6F4-E6CA1E23CC2E}
Point: [...]